Mulitcast event logging
Is there any way to turn off the mulitcast monitoring? Our even manager is filling up with these messages and is shadowing other important events. Thanks in advance,Tony
View ArticleRe: Dependency checking
Up/Down status is reported via ICMP (ping). If it gets marked as down, then it will be listed in the database as Down in the Nodes Table.
View ArticleRe: Dependency checking
Yes, ICMP status is marked in the database. My quesstion is that then a child entity is down does Orion ping the parent for status or look at the last status record in the database. These are two...
View ArticleRe: Dependency checking
Andy: I know exactly what you are saying and it was my criticism as well - a "better" (ie: more accurate) method would be to say "oh, serverA is down? Let me ping it's parent right now. Nope, it's down...
View ArticleMonitoring health of DELL PowerEdge R series + Vmware 5.1
Hi guys... I have been all day dealing and trying to monitor a dell poweredge r410 running vmware esxi5.1.. I dont have SAM, so the idea is to monitor stuff like fan,cpu, nic, raid, array controller,...
View ArticleRe: date format on Orion website
Jaroslaw, Does this explain the behavior well enough? http://thwack.solarwinds.com/message/188651#188651
View ArticleRe: Why is interface utilization 25k% over what it should be?
Will, Can you do a snmpwalk and verify if the ifPhysAddress is showing the correct MAC...
View ArticleRe: why the field "DateTime" is not the current date of the Server in the...
Main Orion Server Details Orion Module NameOrion CoreVersion2012.2.2Service PackNoneNodes currently monitored329Total nodes in licenseunlimitedVolumes currently monitored0Total volumes in...
View Articlewhy the poller data is not correct On the Web but the UnDP UI is correct
do a UnDP poller, Customer the Vendor of Array OID.On the UnDP UI the poller value is correct. but it is not correct on the web.why not insert into the single value to Database? step 1:the poller...
View ArticleRe: Why is interface utilization 25k% over what it should be?
you've probably a bad vendor incapable of reading an 11-year old RFC.ifPhysAddress should be a string of bytes with the actual address in it (6 bytes for Ethernet-like media), and not a displayString...
View ArticleRe: date format on Orion website
Hi Rob, it works, thanks alot! Pozdrawiam/Best RegardsJaroslaw LadygaSystem ConsultantGlobal IT / Operations Chr. Hansen Poland Sp. z O.O.Gdanska 4, Czastkow Mazowiecki05-152 Czosnow,...
View ArticleRe: F5 Issue with MIBs and solarwinds orion v2012.2.2
Hi jiriPsota, I have tried listing the resource from the self IP of the F5 but I still don't get what i need. I have gone into the pollers and looked for the F5 but only my custom pollers are shown....
View ArticleRe: Mulitcast event logging
Hi, thanks for a feedback. Disabling of alerts will apply to all nodes. however if you want to remove multicast polling you have to do that via "list resources".Let me ask you a question, you saying...
View ArticleRe: F5 Issue with MIBs and solarwinds orion v2012.2.2
Can you create and send me the SNMPwalk from your F5. Use SNMPwalk.exe tool in Orion install dir. If you are not able to create complete walk because of timeouts, I will need at least...
View ArticleRe: F5 Issue with MIBs and solarwinds orion v2012.2.2
.1.3.6.1.4.1.3375.2.1.1.1.1.1.0 = INTEGER: 8192.1.3.6.1.4.1.3375.2.1.1.1.1.2.0 = INTEGER: 1.1.3.6.1.4.1.3375.2.1.1.1.1.3.0 = INTEGER: 300.1.3.6.1.4.1.3375.2.1.1.1.1.4.0 = INTEGER:...
View ArticleRe: Alerts - clearing recipient drop list?
Anyone? I thought I'd seen it mentioned as being in one of the files in one of the subdirectories of the product.
View ArticleAlerting - why no semicolons allowed for recipients?
Does anyone know WHY we cannot separate recipients for alerting with semicolons, especially since Microsoft has "trained" us through Outlook that recipients can be separated with a comma or a...